   description => protected'<div>Lifts without separate machine rooms. The drive assembly (and the contr
      ol unit) are located – depending on the manufacturer – at the crest or a
      t the base of the hoistway.<br /><br /></div> <div>The advantage of locatin
      g the drive on the bottom of the hoistway (the pit) is that the valuable top
       floors are not penetrated and hence protected from noise and maintenance ta
      sks – the engine can be accessed without having to cross any apartments (e
      .g. Penthouses).</div>
' (480 chars) related => protectedTW\Twglossary\Domain\Model\Glossaryprototypepersistent entity (uid=65, pid=118) headline => protected'Machine room' (12 chars) subheadline => protected'What is a machine room in lifts?' (32 chars) title => protected'Machine room' (12 chars) description => protected'<div>Fire-proof room, in which the engine and the associated equipment are i
         nstalled.</div> <div>Requirements on a machine room (not complete):<br /><b
         r /></div> <div><ul><li>Minimum height 2.0 m</li><li>Access door mostly T 3
         0 opening outwards</li><li>The door must be able to be opened from the insid
         e without assistance</li><li>Minimum intensity of Illumination 200 lux</li><
         li>Sufficient ventilation and exhaust</li><li>Temperature range from +5 to +
         40 degrees Celsius</li><li>Oil-resistant coat of paint with oil thresholds i
         n the case of hydraulic lifts</li><li>Safe access, guard railing and climbin
         g aids according to specifications</li><li>No additional installations that
         don’t belong to the lift system</li><li>etc.</li></ul></div> <div>See als
         o: European Standards EN &nbsp;</div>
' (799 chars) related => protectedTW\Twglossary\Domain\Model\Glossaryprototypepersistent entitysee above (uid=71, pid=118) uid => protected65 (integer) _localizedUid => protected190 (integer)modified _languageUid => protected3 (integer)modified _versionedUid => protected65 (integer)modified pid => protected118 (integer)
uid => protected71 (integer) _localizedUid => protected196 (integer)modified _languageUid => protected3 (integer)modified _versionedUid => protected71 (integer)modified pid => protected118 (integer)
Glossary

Lifts without machine rooms

Lifts without machine rooms

Lifts without separate machine rooms. The drive assembly (and the control unit) are located – depending on the manufacturer – at the crest or at the base of the hoistway.

The advantage of locating the drive on the bottom of the hoistway (the pit) is that the valuable top floors are not penetrated and hence protected from noise and maintenance tasks – the engine can be accessed without having to cross any apartments (e.g. Penthouses).

see also : Machine room

back to overview